Glensound GS-PASTE 201 - Line Powered TBU (Telephone Balancing Unit)

£342.00 £285.00 (ex. vat)

Glensound GS-PASTE 201

  • Glensound GS-PASTE 201
  • Glensound GS-PASTE 201
  • Glensound GS-PASTE 201

Glensound GS-PASTE 201 - Line Powered TBU (Telephone Balancing Unit)

The Glensound GS-PASTE 201 is a line powered, heavy duty analogue telephone balancing unit. It allows professional audio equipment such as mixers, talkback systems or headphone circuits to be connected to a traditional analogue telephone line.

A tone generator has been included to help with line balancing. Once a line is connected the tone can be switched on, so that the R and C can be balanced accordingly. Instructions for this are printed on the side of the unit.Once the best balance is achieved, the tone can be turned off.

A front panel LED indicates an incoming call. There is also an audible ringer which can be turned off if required.


  • Audio input is line level on a balanced Neutrik XLR
  • Input level control
  • Multi coloured LED indicates level sent to the line


  • Audio output on balance Neutrik XLR.
  • Output level control

Telco Connections
There is an RJ-11 connector for external handset to allow dialling of outgoing calls. An On/Off Hook switch (with indicator) allows answering of calls when and external telephone is not connected.

There is also an RJ-11 connector for connection to a normal telephone line. A recessed switch switches RJ-11 telephone line pairs (there are 2 different standards used Worldwide), for worldwide compatability.


Glensound GS-Paste 201 Features

  • Provides balanced audio input and output from a normal POTS (Plain Old Telephone System) line
  • No batteries or mains required
  • Input compressor (prevents overloading of telephone line)
  • R/C & line balance controls
  • Internal tone generator for line balancing


  • Audio Input:
    • Transformer balanced on neutrik XLR
    • Input impedance: >10k
    • Nominal input level: 0dBu
    • Front panel gain control: +/- 10dB
    • Maximum input level: +18dBu
  • Compressor/ Limiter: Internal efficient compressor/ limiter for controlling levels to the line.
  • Audio Level Indication:
    • Large front panel tri colour LED:
    • BLUE = Off hook and level <-10dBu
    • GREEN = level >-10dBu <-3dBu
    • RED = level >-3dBu
  • Audio Output:
    • Transformer balanced on neutrik XLR
    • Output impedance: 50 Ohms
    • Nominal output level: 0dBu
    • Maximum output level: typically +6dBu (limitation is level of audio on telephone line)
    • Front Panel gain control: +/-10dB
  • Telephone Line:
    • Line Type: Direct Exchange Line (DEL) (standard analogue line used worlwide)
    • Line Connector: RJ14 6P6C (RJ11 6P2C compatible)
    • Connector Pinout: Can be switched between PINS 2/5 and 3/4 (provides Worlwide compatibility)
    • Pinout Switch: Rear panel recessed
Manufacturer Glensound
Model GSPASTE201
Contact Us

Studiocare Professional Audio Ltd.

Unit 2, 56 Evans Road


L24 9PB

+44 (0) 151 707 4545
+44 (0) 845 345 8910

Opening Hours
Mon - Fri: 9:30 - 5:30
Sat - Sun: Closed

How To Find Us
Terms & Conditions
Returns Form
Repair Request
Studiocare on FacebookStudiocare on TwitterStudiocare on Google+” width=Studiocare on YoutubeStudiocare on Pintrest

© Copyright Studiocare Professional Audio Ltd. 2016